Model 1
Model 2
Main Technical Specifications Model 1
Measuring Range:
HC: 0~9,999 ppm (n-Hexane)
CO: 0~10 %
CO : 0~18 % 2
O : 0~25 % 2
NO: 0~5,000 ppm
Measurement Accuracy:
HC: ±12 ppm (abs.) 0~2,000 ppm
±5 % ( rel. ) 0~2,000 ppm (which ever is larger)
±10 % ( rel. ) 2,001~9,999 ppm
CO: ±0.06 % (abs.)
±5 % ( rel. ) (which ever is larger)
CO : ±0.5 % (abs.) 2
±5 % ( rel. ) (which ever is larger)
O : ±0.1 % (abs.) 2
±5 % ( rel. ) (which ever is larger)
NO: ±25 % (abs.)
±4 % ( rel. ) (which ever is larger)
Response Time: Less than 10s for T90
(O , less than 12s. NO, less than 15s) 2
Warm-up Time: 10 min.
(ambient temperature is not lower than 20℃)
Power Supply: AC220V ±10% 50Hz ±1Hz
Net Weight: 6.0Kg
Outer Dimension:
260mm(W) × 180mm(H) × 450mm(D)
Main Technical Specifications Model 2
Measuring Range:
HC: 0~9,999 ppm (n-Hexane)
CO: 0~10 %
CO : 0~18 % 2
O : 0~25 % 2
NO: 0~5,000 ppm
Measurement Accuracy:
HC: ±10 ppm (abs.)
±5 % ( rel. ) (which ever is larger)
CO: ±0.03 % (abs.)
±5 % ( rel. ) (which ever is larger)
CO : ±0.5 % (abs.) 2
±5 % ( rel. ) (which ever is larger)
O : ±0.1 % (abs.) 2
±5 % ( rel. ) (which ever is larger)
NO: ±25 % (abs.)
±4 % ( rel. ) (which ever is larger)
Response Time: Less than 10s for T90
(O , less than 12s. NO, less than 15s) 2
Warm-up Time: 8 min.
(ambient temperature is not lower than 20℃)
Fast measurement can be started at 3 min.
Power Supply: AC220V ±10% 50Hz ±1Hz
Net Weight: 9Kg
Outer Dimension:
310mm(W) × 230mm(H) × 485mm(D)
Main Features and Specifications
Measure concentration of HC, CO, CO2, O and NO
contained in exhaust gases from gasoline engine of
vehicles. Advanced NDIR (non-Dispersive Infrared)
analysis technology is used to measure HC, CO, CO2
and the newest generation of electrochemical
technology is adopted to measure O2 and NO .
Designed with LCD screen for easier setting and
operation.
Automatic calculation and display of A/F (air-fuel-ratio)
and Lambda air ratio .
Emissions from vehicle engine fuels of CNG, LPG and
Ethanol gasoline can be measured.
Small Size, light weight and most convenient for carry.
Designed with inductive clip-on pickup sensor for RPM
measurement.
Designed with oil temperature measurement probe.
Designed with RS-232C digital serial interface.
200 groups of measurement data storage and review.
In compliance with accuracy requirement of ISO 3930
or OIML R99 Class 2.λ
Options and Accessories:
Micro printer.
Various RPM measurement adaptors.
DC12V vehicle power inverter.